14.8 Setting offset temperature (tOF)
As the temperature is measured on the radiator thermo-
stat, the temperature distribution can vary throughout a
room. To adjust this, a temperature offset of ±3.C can
be set. If a nominal temperature of e.g. 20°C is set at the
radiator but the room presents with only 18°C an offset of
-2.0°C needs to be set.
If you use the MAX! Radiator Thermostat
+
in con-
nection with a MAX! Wall Thermostat, the tempera-
ture will be measured at the MAX! Wall Thermostat.
In the MAX! House Solution, all settings of the MAX!
Radiator Thermostat
+
are made via the MAX! soft-
ware.
In the MA X! Room Solution, all settings of the MA X!
Radiator Thermostat
+
are made via the MAX! Wall
Thermostat
+
.
If you use the MAX! Radiator Thermostat
+
in the
MAX! Radiator Solution, please proceed as follows:
 Press the Auto/Menu button for more than 3 seconds.
 Choose the menu item „tOF“ with the handwheel.
 
Turn the handwheel and set the desired offset tempera-
ture (max. ±3.C).
 